LP-O2 (WEST ELECTRICAL CLOSET)
LP-O2
MAIN:M.C.B.RATING:100 ASPACES:30SERVICE: 120/208 V, 3-PHASE, 4-WIREMOUNTING: FLUSHFEEDS FROM: BUILDING DISTRIBUTION / 100 A FEEDERPANEL SCCR: 10 KATRIM: HINGED DOOR, NEMA 1A.I.C.: 10 KAFAULT CURRENT CALCULATED 2026-11-22 / fnv1a32:d055d541AFC: 6.2 KA, uses Eaton Table 4 C values not yet checked against the bookA.I.C. PASS, SCCR PASS
Panel schedule for LP-O2, odd circuits on the left and even circuits on the right
CKTDESCRIPTIONKVACIRCUIT BREAKERBRANCH CIRCUITCVD%PHCKTDESCRIPTIONKVACIRCUIT BREAKERBRANCH CIRCUITCVD%PH
POLETRIPPNGNDPOLETRIPPNGND
11.8120121212--1.07A21.8120121212--1.07A
31.5120121212--2.40B40.72120121212--2.40B
51.8120121212--2.67C61.2120121212--2.67C
72.522012--12--0.77A84.522510--10--1.50A
912----B1010----B
111.2120121212--2.94C121.44120121212--2.13C
13----------------A14----------------A
15--120----------B16--120----------B
17----------------C18----------------C
19----------------A20----------------A
21----------------B22----------------B
23----------------C24----------------C
25----------------A26----------------A
27----------------B28----------------B
29----------------C30----------------C
CONNECTED LOAD: 18.46 KVAPHASE A: 59.2 APHASE B: 47.7 APHASE C: 47.0 AIMBALANCE: 23.7%
WORST COMBINED VOLTAGE DROP: 4.65% AT CKT 11, C405.5.3, uses Table 9 values not yet checked against the book
CALCULATED LOAD: 23.14 KVA (25.17 KVA CONTINUOUS AT 125%)MAXIMUM LOAD: 80.83 A, 81% OF 100 A MAIN, HEAVIEST LINE CCONTINUOUS AT 125%: 80.83 A, 81% OF 100 A MAIN, HEAVIEST LINE C
RECEPTACLESCOUNTED 3.06 KVADEMAND 8.50 KVATable 220.44: first 10 kVA at 100 %, the rest at 50 %, with the 220.14(K) office minimum
MOTORCOUNTED 2.50 KVADEMAND 3.12 KVA220.50 and 430.24: every motor plus 25 % of the largest
OTHER (NAMEPLATE)COUNTED 11.52 KVADEMAND 11.52 KVA220.14(A): nameplate at 100 %
Unreviewed data: the calculated load uses NEC 2020 values not yet checked against the book: 220.14(I) (single or multiple receptacle on one yoke); Table 220.44 (first band limit, first band factor, remainder factor); 220.14(K) (office receptacle minimum).
NOTES: Synthetic demonstration schedule. Connected loads, run lengths, raceways, installed conductor sizes, load categories, served areas, equipment ratings, energy code scope and fault-current inputs are fictional. Table values are not yet checked against the book.
Unreviewed data: 1 C value from Eaton's Short-Circuit Current Calculations (2014), Table 4, three single conductors at 600 V, used on the run to LP-O2, not yet checked against the bulletin: copper in steel conduit: 3 AWG. get_fault_current lists each value and where it is used.

Calculated load

Calculated

23.14 kVA25.17 kVA with continuous loads at 125 %

Maximum load
80.83 A 81 % of the 100 A mainheaviest line C
Continuous at 125 %
80.83 A 81 % of the 100 A mainheaviest line C

At 208 V, three-phase.

Calculated load by category
CategoryCountedDemandRule
Receptacles3.06 kVA8.50 kVATable 220.44: first 10 kVA at 100 %, the rest at 50 %, with the 220.14(K) office minimum
Motor2.50 kVA3.12 kVA220.50 and 430.24: every motor plus 25 % of the largest
Other (nameplate)11.52 kVA11.52 kVA220.14(A): nameplate at 100 %
  • Unreviewed data: 5 table values (220.14(I), Table 220.44, 220.14(K)) not yet checked against the code book.